Sikafloor® -2530 W 2-part water based epoxy coating 

发布时间:2023/05/21

 
Product Data Sheet
Edition 03/03/2012 EN
Sikafloor® -2530 W
1
1/6
Sikafloor®-2530 W
Sikafloor® -2530 W
2-part water based epoxy coating
Product
Description
Sikafloor® -2530 W is a two part, water dispersed, solvent free, coloured, epoxy
resin based coating.
Uses



Coloured epoxy coating for concrete, cement screeds, broadcast systems and
epoxy mortars



Can be subjected to normal up to medium heavy mechanical and chemical
loading



For production areas, warehouses, car park decks, garages, etc.
Characteristics /
Advantages



Good chemical and mechanical resistance



Water vapour permeable



Solvent free



Water dilutable



Odourless



Easy application
Tests
Approval / Standards
Conforms to the requirements for physiological harmlessness according to the 47th
notification of the Federal Health Office, Report No. P 1777-1, Polymer Institute,
Germany.
Conforms to the requirements for decontamination ability (BS 4247, IRAS Ltd., St.
Hellens, UK and to DIN 25 415-1 Report No. 35156, Forschungszentrum Jülich,
Germany.
Conforms to the requirements of DIN 4101-1/14 for Class B1 (combustibility
classification for floorings), Report-No. 16-904136000a, FMPA Stuttgart, Germany,
March 2004.
Product Data
Form
Appearance / Colours
Resin - part A: coloured, liquid
Hardener - part B: white, liquid
Available in various colour shades.
With light colour shades (e.g. yellow or orange) it may be necessary to apply several
coats of Sikafloor® -2530 W to achieve full opacity (hiding power).
Under direct sun radiation there may be some discolouration and colour deviation,
this has no influence on the function and performance of the coating.
Construction2
2/6
Sikafloor® -2530 W
Packaging
Part A: 4.2 kg and 12.6 kg containers
Part B: 1.8 kg and 5.4 kg containers
Part A+B: 6.0 kg and 18 kg ready to mix units
Storage
Storage Conditions/
Shelf-Life
12 months from date of production if stored properly in original, unopened and
undamaged sealed packaging, in dry conditions at temperatures between +5°C and
+30°C. Protect from frost.
Technical Data
Chemical Base
Epoxy, waterborne
Density
Part A: 1.28 kg/l (DIN EN ISO 2811-1)
Part B: 1.09 kg/l
Mixed Resin: 1.22 kg/l
All Density values at +23°C
Solid Content
~ 43% (by volume) / ~ 55% (by weight)
Mechanical /
Physical Properties
Abrasion Resistance
54 mg (CS 10/1000/1000) (14 days / +23°C) (DIN 53 109 (Taber Abrader Test))
Resistance
Chemical Resistance
Resistant to many chemicals. Please ask for a detailed chemical resistance table.
Exposure*
Dry heat
Permanent
+50°C
Short-term max. 7 d
+80°C
Short-term max. 8 h
+100°C
Thermal Resistance
Short-term moist/wet heat* up to +80°C where exposure is only occasional
(i.e. during steam cleaning etc.)
*No simultaneous chemical and mechanical exposure.
System
Information
System Structure
Coating system:
Primer: 1 x Sikafloor® -156 + 10 wt.-% Thinner C
(non absorbent surfaces)
1 x Sikafloor® -2530 W + 5 wt.-% water
(normal absorbent surfaces)
1 x Sikafloor® -156 (strongly absorbent surfaces)
Seal coat smooth: 1 - 2 x Sikafloor® -2530 W
Seal coat textured: 1 - 2 x Sikafloor® -2530 W + 2 wt.-% Extender T
Seal coat for broadcast systems: 2 x Sikafloor® -2530 W
Note: For heavier exposure use Sikafloor® -156 for priming and a two-layer coating
with Sikafloor® -2530 W. 3
3/6
Sikafloor® -2530 W
Application Details
Coating System Product Consumption
Primer Sikafloor® -156 + 10 wt.-%
Thinner C or Sikafloor® -
156 or Sikafloor® -2530
W+5% water
0.3 - 0.5 kg/m²
0.3 - 0.5 kg/m²
0.2 - 0.3 kg/m²
Seal coat smooth 1 - 2 x Sikafloor® -2530 W 0.2 - 0.3 kg/m²/layer
Seal coat textured 1 - 2 x Sikafloor® -2530 W
+
2% Extender T
0.2 - 0.3 kg/m²/layer
Seal coat for broadcast
systems
2 x Sikafloor® -2530 W 0.4 - 0.6 kg/m²
Consumption / Dosage
These figures are theoretical and do not allow for any additional material due to
surface porosity, surface profile, variations in level and wastage etc.
Substrate Quality
The concrete substrate must be sound and of sufficient compressive strength
(minimum 25 N/mm2 ) with a minimum pull off strength of 1.5 N/mm2 .
The substrate must be clean, dry and free of all contaminants such as dirt, oil,
grease, coatings and surface treatments, etc..
If in doubt apply a test area first.
Substrate Preparation
Concrete substrates must be prepared mechanically using abrasive blast cleaning
or scarifying equipment to remove cement laitance and achieve an open textured
surface.
Weak concrete must be removed and surface defects such as blowholes and voids
must be fully exposed.
Repairs to the substrate, filling of blowholes/voids and surface levelling must be
carried out using appropriate products from the Sikafloor® , Sikadur® and Sikagard®
range of materials.
The concrete or screed substrate has to be primed or levelled in order to achieve
an even surface.
High spots must be removed by e.g. grinding.
All dust, loose and friable material must be completely removed from all surfaces
before application of the product, preferably by brush and/or vacuum.
Application
Conditions /
Limitations
Substrate Temperature
+10°C min. / +30°C max.
Ambient Temperature
+10°C min. / +30°C max.
Substrate Moisture
Content
< 6% pbw moisture content.
Test method: Sika® -Tramex meter, CM - measurement or Oven-dry-method.
No rising moisture according to ASTM (Polyethylene-sheet).
Relative Air Humidity
75% r.h. max., adequate fresh air ventilation must be provided to remove excess
moisture during curing.
Dew Point
Beware of condensation!
The substrate and uncured floor must be at least 3°C above dew point to reduce
the risk of condensation or blooming on the floor finish. 4
4/6
Sikafloor® -2530 W
Application
Instructions
Mixing
Part A : part B = 70 : 30 (by weight)
Mixing Time
Prior to mixing, stir part A mechanically. When all of part B has been added to part
A, mix continuously for 2 minutes until a uniform mix has been achieved.
To ensure thorough mixing pour materials into another container and mix again to
achieve a consistent mix.
Over mixing must be avoided to minimise air entrainment.
Mixing Tools
Sikafloor® -2530 W must be thoroughly mixed using a low speed electric stirrer (300
- 400 rpm) or other suitable equipment.
Application Method /
Tools
Prior to application, confirm substrate moisture content, r.h. and dew point.
If > 6% pbw moisture content, Sikafloor® EpoCem® may be applied as a T.M.B.
(temporary moisture barrier) system.
Primer:
Make sure that a continuous, pore free coat covers the substrate. If necessary,
apply two priming coats. When used as a primer always apply by brush.
Seal coat:
Sikafloor® -2530 W is spread evenly by means of a short pile roller.
A seamless finish can be achieved if a “wet” edge is maintained during application.
Sikafloor® -2530 W can also be applied by airless spray (spray pressure ~ 300 bar,
nozzles with a diameter of 0.53 mm / 0.021 inch and a spray angle 60°).
Uneven application of the material and resulting differences in the coating layer
thicknesses may cause differences in “gloss” of the surface.
Cleaning of Tools
Clean all tools and application equipment with water immediately after use.
Hardened and/or cured material can only be removed mechanically.
Temperature Time
+10°C ~ 150 minutes
+20°C ~ 120 minutes
+30°C ~ 60 minutes
Potlife
Before applying Sikafloor® -2530 W on Sikafloor® -156 allow:
Substrate temperature Minimum Maximum
+10°C 24 hours 4 days
+20°C 12 hours 2 days
+30°C 6 hours 1 day
Before applying Sikafloor® -2530 W on Sikafloor® -2530 W allow:
Substrate temperature Minimum Maximum
+10°C 48 hours 7 days
+20°C 20 hours 5 days
+30°C 10 hours 3 days
Waiting Time /
Overcoating
Times are approximate and will be affected by changing ambient conditions
particularly temperature and relative humidity.
When relative air humidity is ≥ 75% the waiting time is increased by at least 24
hours. 5
5/6
Sikafloor® -2530 W
Notes on Application /
Limitations
Do not apply Sikafloor® -2530 W on substrates with rising moisture.
Freshly applied Sikafloor® -2530 W should be protected from damp, condensation
and water for at least 24 hours.
Avoid puddles on surface with the primer.
Always ensure adequate fresh air ventilation when using Sikafloor® -2530 W in
confined spaces to avoid curing problems.
The “gloss” of the finish can vary with temperature and the absorbency of the
substrate.
Tools
Recommended Supplier of Tools:
PPW-Polyplan-Werkzeuge GmbH, Phone: +49 40/5597260, www.polyplan.com
The incorrect assessment and treatment of cracks may lead to a reduced service
life and reflective cracking.
For exact colour matching, ensure the Sikafloor® -2530 W in each area is applied
from the same control batch numbers.
For spray application the use of protective health & safety equipment is mandatory!
Under certain conditions, underfloor heating or high ambient temperatures
combined with high point loading, may lead to imprints in the resin.
If heating is required do not use gas, oil, paraffin or other fossil fuel heaters, these
produce large quantities of both CO2 and H2O water vapour, which may adversely
affect the finish. For heating use only electric powered warm air blower systems.
Curing Details
Temperature Foot traffic Light traffic Full cure
+10°C ~ 48 hours ~ 5 days ~ 10 days
+20°C ~ 20 hours ~ 3 days ~ 7 days
+30°C ~ 10 hours ~ 2 days ~ 5 days
Applied Product ready
for use
Note: Times are approximate and will be affected by changing ambient conditions.
Cleaning /
Maintenance
Methods
To maintain the appearance of the floor after application, Sikafloor® -2530 W must
have all spillages removed immediately and must be regularly cleaned using rotary
brush, mechanical scrubbers, scrubber dryer, high pressure washer, wash and
vacuum techniques etc. using suitable detergents and waxes.
Value Base
All technical data stated in this Product Data Sheet are based on laboratory tests.
Actual measured data may vary due to circumstances beyond our control.
Local Restrictions Please note that as a result of specific local regulations the performance of this
product may vary from country to country. Please consult the local Product Data
Sheet for the exact description of the application fields.
Health and Safety
Information
For information and advice on the safe handling, storage and disposal of chemical
products, users shall refer to the most recent Material Safety Data Sheet containing
physical, ecological, toxicological and other safety-related data.6
6/6
Sikafloor® -2530 W
Notes:
The information, and, in particular, the recommendations relating to the application and end-use of Sika products, are given in
good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under
normal conditions in accordance with Sika’s recommendations. In practice, the differences in materials, substrates and actual
site conditions are such that no warranty in respect of merchantability or of fitness for a particular purpose, nor any liability
arising out of any legal relationship whatsoever, can be inferred either from this information, or from any written
recommendations, or from any other advice offered. The user of the product must test the product’s suitability for the intended
application and purpose. Sika reserves the right to change the properties of its products. The proprietary rights of third parties
must be observed. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the
most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
Sika (China) Ltd.
No.28 Jingdong Road, Suzhou Industrial Park,
JiangSu,P.R.China
Postal Code: 215121
 
ISO 9001: 2008 ISO 14001:2004
Certificate No.:CC3576 Certificate No.:CC3577
The product is manufactured under a HKQAA
ISO9001/ISO14001
certified quality/environmental management system.
 
Construction
Construction
Construction