Sikafloor® -330 

发布时间:2023/05/11

Sikafloor® -330
2-part PUR part of the Sika® -ComfortFloor® and
Sika® -ComfortFloor® Pro System
Product
Description
Sikafloor® -330 is a two parts, solvent free, very low VOC emission certified, elastic,
self-smoothing PUR resin.
Uses

Elastic smooth wearing course for the Sika® -ComfortFloor® and
Sika® -ComfortFloor® Pro Systems

Particularly suitable for hospitals, schools, sales premises, showrooms,
entrance halls, lobbies, open-plan offices, museums

For interior use only
Characteristics /
Advantages

Very low VOC emission

Solvent free

Permanently elastic (crack bridging)

Good mechanical resistance

Reduces footfall sound

Easy to apply

Low maintenance finish
Test
Approval / Standards
Fire classification acc. to EN 13501-1, Test report 08-199, Universiteit Gent
Product Data
Form
Appearance / Colours
Resin - part A: coloured, liquid
Hardener - part B: light brown, transparent, liquid
10 Standard colours available:
Grey white, beige, light grey, middle grey, dark grey, light blue, dark blue, light
green, dark green, red.
Be aware that the colour of the Sikafloor® -330 has to be approx. adjusted to the
colour of the Sikafloor® -305 W.
Packaging
Part A: 15.8 kg containers
Part B: 4.2 kg containers
Part A+B: 20.0 kg ready to mix units
Storage
Storage Conditions /
Shelf-Life
6 months from date of production if stored properly in original, unopened and
undamaged sealed packaging, in dry conditions at temperatures between +5°C and
+30°C.
Construction2
2/5
Sikafloor®-330
Prolonged vibrations and higher ambient temperatures during transportation can
result in settling of the A Component, which makes mixing more difficult.
Prolonged storage at low temperatures can result in crystallizing of the B
Component.
Technical Data
Chemical Base
PUR
Density
Mixed Resin: ~ 1.40 kg/l
All Density values at +23°C.
Solid Content
~ 100% (by volume) / ~ 100% (by weight)
Mechanical / Physical
Properties
Tensile Strength
Resin: ~ 8.0 N/mm² (14 days / +23°C) (DIN 53504)
Bond Strength
> 1.5 N/mm2 (failure in concrete) (EN 13892-8)
Shore A Hardness
Resin: ~ 80 (14 days / +23°C)
(DIN 53505)
Elongation at Break
Resin: ~ 180 % (14 days / +23°C) (DIN 53504)
Tear Growth Strength
Resin: ~ 25 N/mm (14 days / +23°C) (ISO 34-1)
Resistance
Chemical Resistance
Sikafloor® -330 always has to be sealed with Sikafloor® -305 W.
Therefore, refer to chemical resistance chart of Sikafloor® -305 W.
System
Information
System Structure Sika® -ComfortFloor® :
Primer: 1 x Sikafloor® -161
Wearing course: 1 x Sikafloor® -330
Seal coat (mandatory): 1-2 x Sikafloor® -305 W
Sika® -ComfortFloor® Pro:
Primer: 1 x Sikafloor® -Comfort Adhesive
Rubber Shockpad: 1 x Sikafloor® -Comfort Regupol 6015 H
Porefiller: 1-2 x Sikafloor® -Comfort Porefiller
Wearing course: 1 x Sikafloor® -330
Seal coat (mandatory): 1-2 x Sikafloor® -305 W
Application Details
Coating System Product Consumption
Primer Sikafloor® -161 ~ 0.5 kg/m²
Levelling (if required) Sikafloor® -161 levelling mortar Refer to PDS of Sikafloor® -161
Self-smoothing wearing
course (film thickness
~ 2.0 mm)
Sikafloor® -330 2.80 kg/m²
Seal coat Sikafloor® -305 W 1-2 x ~0.13 kg/m²/layer
Consumption / Dosage
These figures are theoretical and do not allow for any additional material due to
surface porosity, surface profile, variations in level and wastage etc.
Substrate Quality
Concrete substrates must be sound and of sufficient compressive strength
(minimum 25 N/mm2 ) with a minimum pull off strength of 1.5 N/mm2 .
The substrate must be clean, dry and free of all contaminants such as dirt, oil,
grease, coatings and surface treatments, etc.
If in doubt, apply a test area first. 3
3/5
Sikafloor®-330
Substrate Preparation
Concrete substrates must be prepared mechanically using abrasive blast cleaning
or scarifying equipment to remove cement laitance and achieve an open textured
surface.
Weak concrete must be removed and surface defects such as blowholes and voids
must be fully exposed.
Repairs to the substrate, filling of blowholes/voids and surface levelling must be
carried out using appropriate products from the Sikafloor® , SikaDur® and SikaGard®
range of materials.
The concrete or screed substrate has to be primed or levelled in order to achieve an
even surface.
High spots must be removed by e.g. grinding.
All dust, loose and friable material must be completely removed from all surfaces
before application of the product, preferably by brush and/or vacuum.
Application
Conditions /
Limitations
Substrate Temperature
+10°C min. / +30°C max.
Ambient Temperature
+10°C min. / +30°C max.
Substrate Moisture
Content
< 4% pbw moisture content.
Test method: Sika® -Tramex meter, CM - measurement or Oven-dry-method.
No rising moisture according to ASTM (Polyethylene-sheet).
Relative Air Humidity
80% r.h. max.
Dew Point
Beware of condensation!
The substrate and uncured floor must be at least 3°C above dew point to reduce the
risk of condensation or blooming on the floor finish.
Application
Instructions
Mixing
Part A : part B = 79 : 21 (by weight)
Mixing Time
Check if the B component is free of crystallization. Should crystals be found the B
component has to be heated to 60°C until all crystals redissolve.
Prior to mixing, stir part A mechanically. When all of part B has been added to part
A, mix continuously for 2 minutes until a uniform mix has been achieved.
To ensure thorough mixing pour materials into another container and mix again to
achieve a consistent mix.
Over mixing must be avoided to minimise air entrainment.
Mixing Tools
Sikafloor® -330 must be thoroughly mixed using a low speed electric stirrer (300 -
400 rpm) or other suitable equipment.
Application Method /
Tools
Prior to application, confirm substrate moisture content, r.h. and dew point.
If > 4% pbw moisture content, Sikafloor® EpoCem® may be applied as a T.M.B.
(temporary moisture barrier) system.
Levelling:
Rough surfaces need to be levelled first. Therefore use e.g. Sikafloor® -161 levelling
mortar (see PDS).
Self-smoothing system 2.0 mm:
Sikafloor® -330 is poured and spread evenly by means of a serrated trowel. Roll
immediately in two directions with a spiked roller to ensure even thickness and to
remove entrapped air.
Once Sikafloor® -330 is “tack-free” apply the seal coat.
Seal coat:
Top coats are uniformly spread using a short pile roller.
A seamless finish can be achieved if a “wet” edge is maintained during application.4
4/5
Sikafloor®-330
Cleaning of Tools
Clean all tools and application equipment with Thinner C immediately after use.
Hardened and/or cured material can only be removed mechanically.
Temperatures
Time
+10°C
~ 21 minutes
+20°C
~ 15 minutes
+30°C
~ 12 minutes
Potlife
Before applying Sikafloor® -330 on Sikafloor® -161 allow:
Substrate temperature Minimum Maximum
+10°C 24 hours 3 days
+20°C 12 hours 2 days
+30°C 6 hours 1 day
Before applying Sikafloor® -305 W on Sikafloor® -330 allow:
Substrate temperature Minimum Maximum
+10°C 24 hours 72 hours
+20°C 18 hours 48 hours
+30°C 16 hours 36 hours
Waiting Time /
Overcoating
Times are approximate and will be affected by changing ambient conditions
particularly temperature and relative humidity.
Notes on Application /
Limitations
Do not apply Sikafloor® -330 on substrates with rising moisture.
Do not apply on substrate surfaces with a slope > 1%.
Freshly applied Sikafloor® -330 must be protected from damp, condensation and
water for at least 24 hours.
Avoid puddles on the surface with the primer.
Uncured material reacts in contact with water (foaming). During application care
must be taken that no sweat drops into fresh Sikafloor® -330 (wear head and wrist
bands)
Tools
Serrated trowel for smooth wearing layer:
e.g. Large-Surface Scrapper No. 565, Toothed blades No. 25
Recommended supplier of tools:
TECHNO-Werkzeuge A.E; Vertriebs GmbH
Dieselstr. 44; 42579 Heiligenhaus, Phone: 02056 / 9846-0
Info@Techno-Vertrieb.de; Homepage: http://www.techno-vertrieb.de
PPW-Polyplan-Werkzeuge GmbH, Phone: +49 40/5597260, www.polyplan.com.
If heating is required do not use gas, oil, paraffin or other fossil fuel heaters, these
produce large quantities of both CO2 and H2O water vapour, which may adversely
affect the finish. For heating use only electric powered warm air blower systems
Curing Details
Temperature Foot traffic Full cure
+10°C ~ 24 hours ~ 72 hours
+20°C ~ 18 hours ~ 60 hours
+30°C ~ 16 hours ~ 48 hours
Applied Product ready
for use
Note: Times are approximate and will be affected by changing ambient conditions 5
5/5
Sikafloor®-330
Cleaning /
Maintenance
Methods
To maintain the appearance of the floor after application, Sikafloor® -330 must have
all spillages removed immediately and be regularly cleaned using rotary brush,
mechanical scrubbers, scrubber dryer, high pressure washer, wash and vacuum
techniques etc using suitable detergents and waxes.
Value Base
All technical data stated in this Product Data Sheet are based on laboratory tests.
Actual measured data may vary due to circumstances beyond our control.
Local Restrictions Please note that as a result of specific local regulations the performance of this
product may vary from country to country. Please consult the local Product Data
Sheet for the exact description of the application fields.
Health and Safety
Information
For information and advice on the safe handling, storage and disposal of chemical
products, users shall refer to the most recent Material Safety Data Sheet containing
physical, ecological, toxicological and other safety-related data.
 
Notes:
The information, and, in particular, the recommendations relating to the application and end-use of Sika products, are given in
good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under
normal conditions in accordance with Sika’s recommendations. In practice, the differences in materials, substrates and actual
site conditions are such that no warranty in respect of merchantability or of fitness for a particular purpose, nor any liability
arising out of any legal relationship whatsoever, can be inferred either from this information, or from any written
recommendations, or from any other advice offered. The user of the product must test the product’s suitability for the intended
application and purpose. Sika reserves the right to change the properties of its products. The proprietary rights of third parties
must be observed. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the
most recent issue of the local Product Data Sheet f
or the product concerned, copies of which will be supplied on request.
Sika (China) Ltd.
No.28 Jingdong Road, Suzhou Industrial Park,
JiangSu,P.R.China
 
ISO 9001: 2008 ISO 14001:2004
Certificate No.:CC3576 Certificate No.:CC3577
The product is manufactured under a HKQAA
ISO9001/ISO14001
certified quality/environmental management system.
 
Construction